0,0 → 1,824 |
; PSI Config File |
; |
; @category PHP |
; @package PSI |
; @author Michael Cramer <BigMichi1@users.sourceforge.net> |
; @copyright 2009 phpSysInfo |
; @license http://opensource.org/licenses/gpl-2.0.php GNU General Public License version 2, or (at your option) any later version |
; @version SVN: $Id: phpsysinfo.ini.new 705 2012-11-11 00:33:29Z namiltd $ |
; @link http://phpsysinfo.sourceforge.net |
|
[main] |
; ******************************** |
; MAIN PARAMETERS |
; ******************************** |
|
; Turn on debugging of some functions and include errors and warnings in xml and provide a popup for displaying errors |
; - false : no debug information are stored in xml or displayed |
; - true : debug information stored in xml and displayed *be careful if set this to true, may include sensitive information from your pc* |
; |
DEBUG=false |
|
; Turn on logging/unlogging of functions executeProgram() and rfts() |
; example : executeProgram () and rfts () record the results to the "/tmp/phpsysinfo.log" file |
; LOG="/tmp/phpsysinfo.log" |
; example : executeProgram () and rfts () read the results from the "/tmp/phpsysinfo.log" file |
; LOG="-/tmp/phpsysinfo.log" |
; example : executeProgram () and rfts () read the results from the "/tmp/phpsysinfo.log" file |
; LOG="+/tmp/phpsysinfo.log", if lack in the log file it runs normally |
; |
LOG=false |
|
; Turn on/off compression for JavaScript file |
; - JS_COMPRESSION=false //no compression (recommended with slow processor) |
; - JS_COMPRESSION="None" //code minimizing |
; - JS_COMPRESSION="Normal" //code packing |
; |
JS_COMPRESSION="Normal" |
|
; Additional paths where to look for installed programs |
; Example : ADD_PATHS="/opt/bin,/opt/sbin" |
; |
ADD_PATHS=false |
|
; List of IP addresses of clients authorized to run |
; Example : ALLOWED="127.0.0.1,192.168.1.48" //allowed IP 127.0.0.1 and 192.168.1.48 |
; ALLOWED=false //no IP checking |
; |
ALLOWED=false |
|
; List of sudo commands |
; Example : SUDO_COMMANDS="iptables-save" //execute "sudo iptables-save" instead "iptables-save" |
; SUDO_COMMANDS=false //no sudo commands |
; |
SUDO_COMMANDS=false |
|
; Order of data blocks |
; Example : BLOCKS="vitals,hardware,memory,filesystem,network,voltage,current,temperature,fans,power,other,ups" or BLOCKS=true //default order |
; BLOCKS=false //hide all blocks |
; |
BLOCKS=true |
|
|
; Plugins that should be included in xml and output |
; List of plugins should look like "plugin,plugin,plugin". See /plugins directory |
; - PLUGINS="MDStatus,PS" //list of plugins |
; - PLUGINS=false //no plugins |
; included plugins: |
; - Raid - show the software, fake, zpool or megaraid RAID status |
; - PS - show a process tree of all running processes |
; - PSStatus - show a graphical representation if a process is running or not |
; - Quotas - show a table with all quotas that are active and there current state |
; - SMART - show S.M.A.R.T. information from drives that support it |
; - BAT - show battery state on a laptop, tablet or phone |
; - UpdateNotifier - show update notifications (only for Ubuntu server) |
; - SNMPPInfo - show printers info via SNMP |
; - Uprecords - show uprecords info |
; - Iptables - show iptables rules list |
; - PingTest - show Ping Test info |
; - StableBit - show StableBit Scanner info (WinNT) |
; - HyperV - show Hyper-V info (WinNT) |
; - Docker - show docker stats |
; |
PLUGINS=false |
|
|
; ******************************** |
; DISPLAY PARAMETERS |
; ******************************** |
|
|
; Define the default display mode |
; auto: let user browser choose the mode |
; dynamic: use javascript to refresh data |
; static: static page (use metatag to reload page) |
; bootstrap: use twitter bootstrap template |
; |
DEFAULT_DISPLAY_MODE="dynamic" |
|
|
; Define the default language |
; |
DEFAULT_LANG="en" |
|
|
; Define the default template |
; |
DEFAULT_TEMPLATE="cream" |
|
|
; Define the default template for frontend "bootstrap" |
; |
DEFAULT_BOOTSTRAP_TEMPLATE="phpsysinfo" |
|
|
; Show or hide language picklist |
; |
SHOW_PICKLIST_LANG=false |
|
|
; Show or hide template picklist |
; |
SHOW_PICKLIST_TEMPLATE=false |
|
|
; Show CPU list expanded |
; |
SHOW_CPULIST_EXPANDED=false |
|
|
; Show CPU info expanded |
; |
SHOW_CPUINFO_EXPANDED=false |
|
|
; Show memory infos expanded |
; |
SHOW_MEMORY_INFOS_EXPANDED=false |
|
|
; Hide loader for frontend "bootstrap" |
; |
HIDE_BOOTSTRAP_LOADER=true |
|
|
; Define the interval for refreshing data in ms |
; - 0 : disabled |
; - 1000 : 1 second |
; Default is 60 seconds |
; |
REFRESH=60000 |
|
|
; Show a graph for current cpuload |
; - true : displayed, but it's a performance hit (because we have to wait to get a value, 1 second) |
; - "compact" : displayed like above but in compact mode |
; - false : will not be displayed |
; |
LOAD_BAR=true |
|
|
; Display the virtual host name and address |
; - Default is canonical host name and address |
; - Use USE_VHOST=true to display virtual host name. |
; |
USE_VHOST=false |
|
|
; Controls the units & format for network, memory and filesystem |
; - 1 KiB = 2^10 bytes = 1,024 bytes |
; - 1 KB = 10^3 bytes = 1,000 bytes |
; - "B" everything is in Byte |
; - "PiB" everything is in PeBiByte |
; - "TiB" everything is in TeBiByte |
; - "GiB" everything is in GiBiByte |
; - "MiB" everything is in MeBiByte |
; - "KiB" everything is in KiBiByte |
; - "auto_binary" everything is automatic done if value is to big for, e.g MiB then it will be in GiB |
; - "PB" everything is in PetaByte |
; - "TB" everything is in TeraByte |
; - "GB" everything is in GigaByte |
; - "MB" everything is in MegaByte |
; - "KB" everything is in KiloByte |
; - "auto_decimal" everything is automatic done if value is to big for, e.g MB then it will be in GB |
; |
BYTE_FORMAT="auto_binary" |
|
|
; Format in which temperature is displayed |
; - "c" shown in celsius |
; - "f" shown in fahrenheit |
; - "c-f" both shown first celsius and fahrenheit in braces |
; - "f-c" both shown first fahrenheit and celsius in braces |
; |
TEMP_FORMAT="c" |
|
|
; Show devices infos |
; Example : SHOW_DEVICES_INFOS=true |
; |
SHOW_DEVICES_INFOS=false |
|
|
; Show devices serial number |
; Example : SHOW_DEVICES_SERIAL=true |
; |
SHOW_DEVICES_SERIAL=false |
|
|
; Format in which datetime is displayed |
; - "UTC" shown as UTC string |
; - "locale" shown as Locale string |
; |
DATETIME_FORMAT="UTC" |
|
|
; ******************************** |
; SENSORS PARAMETERS |
; ******************************** |
|
|
; Define the motherboard monitoring program |
; We support the following programs so far |
; - HDDtemp http://www.guzu.net/linux/hddtemp.php (Linux) |
; - LMSensors http://www.lm-sensors.org/ (Linux) |
; - Healthd http://healthd.thehousleys.net/ (FreeBSD) |
; - HWSensors http://www.openbsd.org/ (OpenBSD) |
; - MBMon http://www.nt.phys.kyushu-u.ac.jp/shimizu/download/download.html (FreeBSD/Linux/NetBSD/OpenBSD) |
; - MBM5 http://mbm.livewiredev.com/ (data from file data/MBM5.csv - WinNT) |
; - Coretemp No addon tool neded (FreeBSD/Linux) |
; - IPMItool http://ipmitool.sourceforge.net/ (Linux) |
; - FreeIPMI http://www.gnu.org/software/freeipmi/ (FreeBSD/Linux/OpenBSD/SunOS) |
; - IPMIutil http://ipmiutil.sourceforge.net/ (Darwin/FreeBSD/Linux/SunOS/WinNT) |
; - K8Temp http://hur.st/k8temp/ (DragonFly/FreeBSD/NetBSD/OpenBSD) |
; - PiTemp No addon tool neded (Raspberry Pi and Banana Pi - Linux) |
; - OHM http://openhardwaremonitor.org/ (WinNT) |
; - ThermalZone No addon tool neded (WinNT/Linux/Android) |
; - QTSsnmp SNMP service enabled and snmp-utils package installed: opkg install snmp-utils (QNAP - QTS Linux) |
; - Hwmon No addon tool neded (Linux) |
; - SpeedFan http://www.almico.com/speedfan.php (required tool packaged in: tools/speedfan/SpeedFanGet_bin.zip) (WinNT) |
; - Thinkpad No addon tool neded (Lenovo Thinkpad - Linux) |
; |
; Example: If you want to use lmsensors : SENSOR_PROGRAM="LMSensors" |
; If you want to use lmsensors and IPMItool: SENSOR_PROGRAM="LMSensors,IPMItool" |
; |
SENSOR_PROGRAM=false |
|
|
; Show events of sensors |
; - true : show events |
; - false : do not show events |
; |
SENSOR_EVENTS=true |
|
|
; Sort sensors list |
; |
SORT_SENSORS_LIST=false |
|
|
; Some sensors programs contain an additional configuration in the relevant sections [sensor_...] |
|
|
; ******************************** |
; FILESYSTEM PARAMETERS |
; ******************************** |
|
|
; Show mount point |
; - true : show mount point |
; - false : do not show mount point |
; |
SHOW_MOUNT_POINT=true |
|
|
; Show mount option |
; - true : show mount option |
; - false : do not show mount option |
; |
SHOW_MOUNT_OPTION=true |
|
|
; Show mount credentials |
; - true : show mount credentials |
; - false : do not show mount credentials |
; |
SHOW_MOUNT_CREDENTIALS=false |
|
|
; Show inode usage |
; - true : display used inodes in percent |
; - false : hide them |
; |
SHOW_INODES=false |
|
|
; Hide mounts |
; Example : HIDE_MOUNTS="/home,/usr" |
; |
; HIDE_MOUNTS="/dev,/dev/shm,/run,/run/user/0,/var/tmp/havp,/sys/fs/cgroup" |
HIDE_MOUNTS="" |
|
|
; Filesystem usage warning threshold in percent |
; - 0 : disabled |
; - 90 : 90% |
; Default is 90% |
; |
FS_USAGE_THRESHOLD=90 |
|
|
; Ignore usage and usage threshold for filesystem types |
; Example : IGNORE_THRESHOLD_FS_TYPES="iso9660, squashfs, devfs, devtmpfs, lxfs, udf, UDF, CDFS" |
; |
IGNORE_THRESHOLD_FS_TYPES="iso9660, squashfs, devfs, devtmpfs, lxfs, udf, UDF, CDFS" |
|
|
; Ignore usage of mounts |
; Example : IGNORE_USAGE="/root,/mnt/c" |
; |
IGNORE_USAGE="" |
|
|
; Ignore free space size of mounts |
; Example : IGNORE_FREE="/zfs/space,/zfs/data" |
; |
IGNORE_FREE="" |
|
|
; Hide filesystem types |
; Example : HIDE_FS_TYPES="tmpfs,devtmpfs,usbfs,bstfolder" |
; |
HIDE_FS_TYPES="tmpfs,devtmpfs" |
|
|
; Hide partitions |
; Example : HIDE_DISKS="rootfs,/dev/sda1" |
; HIDE_DISKS=true //hide all partitions |
; |
HIDE_DISKS="" |
|
|
; ******************************** |
; NETWORK PARAMETERS |
; ******************************** |
|
|
; Hide network interfaces |
; Example : HIDE_NETWORK_INTERFACE="eth0,sit0" |
; HIDE_NETWORK_INTERFACE=true //hide all network interfaces |
; |
HIDE_NETWORK_INTERFACE="lo,tun0" |
|
|
; Show network interfaces infos for Linux, Android, FreeBSD, NetBSD, OpenBSD, Haiku, Darwin, SunOS, Minix, QNX and WinNT |
; Example : SHOW_NETWORK_INFOS=true |
; |
SHOW_NETWORK_INFOS=true |
|
|
; Hide MAC address in the infos |
; |
HIDE_NETWORK_MACADDR=false |
|
|
; Sort network interfaces list |
; |
SORT_NETWORK_INTERFACES_LIST=false |
|
|
; Show network infos expanded |
; |
SHOW_NETWORK_INFOS_EXPANDED=false |
|
|
; Show network active speed |
; - true : display network active speed |
; - "bps" : display network active speed in bits per second (b/s, Kb/s, etc...) |
; - false : hide them |
; |
SHOW_NETWORK_ACTIVE_SPEED=true |
|
|
; ******************************** |
; UPS PARAMETERS |
; ******************************** |
|
|
; Define the ups monitoring program |
; We support the following programs so far |
; - Apcupsd http://www.apcupsd.com/ |
; - Nut http://www.networkupstools.org/ |
; - PowerSoftPlus http://ever.eu/ |
; - pmset based on the result of the command "pmset -g batt" on Darwin system |
; - SNMPups monitoring via Simple Network Management Protocol (SNMP) |
; |
; Example: If you want to use Apcupsd : UPS_PROGRAM="Apcupsd" |
; If you want to use Apcupsd and Nut : UPS_PROGRAM="Apcupsd,Nut" |
; |
UPS_PROGRAM=false |
|
|
; Apcupsd supports multiple UPSes |
; You can specify comma delimited list in the form <hostname>:<port> or <ip>:<port>. The defaults are: 127.0.0.1:3551 |
; See the following parameters in apcupsd.conf: NETSERVER, NISIP, NISPORT |
; It uses the defaults if not specified. |
; |
UPS_APCUPSD_LIST=false |
|
|
; Apcupsd has a CGI monitoring utility called apcupsd-cgi |
; You can set the parameter below to true if you have it installed - this will add apcupsd-cgi links to the UPS tree |
; |
UPS_APCUPSD_CGI_ENABLE=false |
|
|
; Nut supports multiple UPSes |
; You can specify comma delimited list in the form <hostname>:<port> or <ip>:<port>. The defaults are: 127.0.0.1:3493 |
; See the following parameters in upsd.conf: LISTEN |
; It uses the defaults if not specified. |
; |
UPS_NUT_LIST=false |
|
|
; SNMPups supports multiple UPSes |
; You can specify comma delimited list in the form <hostname>:<port> or <ip>:<port>. The default port is 161 |
; List must be specified. |
; |
UPS_SNMPUPS_LIST=false |
|
|
; define how to access the SNMP data |
; - "php-snmp" execute php snmprealwalk function (php-snmp module must be installed) |
; - "command" execute snmpwalk command |
; |
UPS_SNMPUPS_ACCESS="php-snmp" |
|
|
; ******************************** |
; SENSORS PROGRAMS PARAMETERS |
; ******************************** |
|
|
[sensor_hddtemp] |
; Hddtemp motherboard monitoring program configuration |
; |
; If the hddtemp program is available we can read the temperature, if hdd is smart capable |
; !!ATTENTION!! hddtemp might be a security issue |
; - ACCESS="command" //read data from 'hddtemp' command (must be set suid) |
; - ACCESS="tcp" //read data from hddtemp deamon (localhost:7634) |
; |
ACCESS="command" |
|
[sensor_lmsensors] |
; LMSensors motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'sensors' command |
; - ACCESS="data" //read data from file data/lmsensors.txt |
; |
ACCESS="command" |
|
[sensor_healthd] |
; Healthd motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'healthdc' command |
; - ACCESS="data" //read data from file data/healthd.txt |
; |
ACCESS="command" |
|
[sensor_mbmon] |
; MBMon motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'mbmon -c 1 -r' command |
; - ACCESS="data" //read data from file data/mbmon.txt |
; - ACCESS="tcp" //read data from mbmon deamon (localhost:411) |
; |
ACCESS="command" |
|
[sensor_ipmitool] |
; IPMItool motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'ipmitool sensor -v' command |
; //if access error execute first: chmod 666 /dev/ipmi0 |
; - ACCESS="data" //read data from file data/ipmitool.txt |
; |
ACCESS="command" |
|
[sensor_freeipmi] |
; FreeIPMI motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'ipmi-sensors --output-sensor-thresholds' program |
; - ACCESS="data" //read data from file data/freeipmi.txt |
; |
ACCESS="command" |
|
[sensor_ipmiutil] |
; IPMIutil motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'ipmiutil sensor -stw' command |
; //if access error execute first: chmod 666 /dev/ipmi0 |
; - ACCESS="data" //read data from file data/ipmiutil.txt |
; |
ACCESS="command" |
|
[sensor_k8temp] |
; K8Temp motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'k8temp' command |
; - ACCESS="data" //read data from file data/k8temp.txt |
; |
ACCESS="command" |
|
[sensor_speedfan] |
; SpeedFan motherboard monitoring program configuration |
; |
; - ACCESS="command" //read data from 'speedfanget' command |
; - ACCESS="data" //read data from file data/speedfan.txt |
; |
ACCESS="command" |
|
|
; ******************************** |
; PLUGINS PARAMETERS |
; ******************************** |
|
|
[bat] |
; BAT Plugin configuration |
|
; define how to access the battery statistic data |
; - "command" on Linux and Android read data from /proc/acpi/battery/BAT0/info and /proc/acpi/battery/BAT0/state |
; or on newer kernel from /sys/class/power_supply/ |
; or from 'upower -d' command (if UPOWER is true) |
; on Android read data from /sys/class/power_supply/ |
; on Darwin read data from 'ioreg -w0 -l -n AppleSmartBattery -r' command |
; on FreeBSD read data from 'acpiconf -i batt' command |
; on OpenBSD read data from 'sysctl hw.sensors.acpibat0' command |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "bat_info.txt" and "bat_state.txt"; content is the output |
; from "cat /proc/acpi/battery/BAT0/info" and "cat /proc/acpi/battery/BAT0/state") |
; |
ACCESS="command" |
|
; on Lunux try executing 'upower -d' command |
; |
UPOWER=false |
|
; Show battery serial number |
; |
SHOW_SERIAL=false |
|
|
[raid] |
; Raid Plugin configuration |
|
; define how to access the raid statistic data |
; - "command" - mdstat: file "/proc/mdstat" is read (on Linux only) |
; - dmraid: command "dmraid -s -vv 2>&1" is run (on Linux only) |
; If access error try execute first: chmod 4755 /sbin/dmraid |
; This method is not recommended for safety reasons! |
; - megactl: command "megactl" (on Linux only) |
; downloaded from http://sourceforge.net/projects/megactl/ or http://github.com/hmage/megactl |
; If permission error try execute first: chmod 4755 /usr/sbin/megactl |
; - megasasctl: command "megasasctl" (on Linux only) |
; downloaded from http://sourceforge.net/projects/megactl/ or http://github.com/hmage/megactl |
; If permission error try execute first: chmod 4755 /usr/sbin/megasasctl |
; - graid: command "graid list" is run (on FreeBSD only) |
; - zpool: command "zpool status" is run |
; - idrac: command "snmpwalk -Ona -c public -v 1 -r 0 -t 3 {device} .1.3.6.1.4.1.674.10892.5.5.1.20" is run |
; - "php-snmp"- idrac: execute php snmprealwalk function (php-snmp module must be installed) |
; - for others the option is inactive (uses "command" instead) |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "raidmdstat.txt" or "raiddmraid.txt" or "raidmegactl.txt" |
; or "raidmegasasctl" or "raidgraid.txt" or "raidzpool.txt" or "raididrac{device_number}.txt") |
; |
ACCESS="command" |
|
; define possible programs |
PROGRAM="mdstat,dmraid,megactl,megasasctl,graid,zpool,idrac" |
|
; Hide RAID devices |
; Example : HIDE_DEVICES="md127" |
; |
HIDE_DEVICES="" |
|
; |
; string contains a list of IDRAC devices that are checked |
; Example : IDRAC_DEVICES="192.168.0.120" |
; |
IDRAC_DEVICES="" |
|
[ps] |
; PS Plugin configuration |
|
; define how to access the ps statistic data |
; - "command" ps command is run everytime the block gets refreshed or build / on WINNT |
; information is retrieved everytime through WMI |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "ps.txt"; content is the output from "ps -axo pid,ppid,pmem,args") |
; |
ACCESS="command" |
|
; Memory Usage info |
; |
MEMORY_USAGE=true |
|
; CPU Usage info |
; |
CPU_USAGE=true |
|
; Show kthreadd child list expanded |
; |
SHOW_KTHREADD_EXPANDED=false |
|
; Show PID 1 child list expanded |
; |
SHOW_PID1CHILD_EXPANDED=false |
|
|
[psstatus] |
; PSStatus Plugin configuration |
|
; define how to access the psstatus statistic data |
; - "command" pidof command is run everytime the block gets refreshed or build / on WINNT |
; information is retrieved everytime through WMI |
; - "data" a file must be available in the data directory of the phpsysinfo installation |
; with the filename "psstatus.txt"; content is the output from |
; <code>for ps in "apache2" "mysqld" "sshd"; do echo $ps "|" `pidof -s -x "$ps"`; done</code> |
; |
ACCESS="command" |
|
; Regular expression search in the process name (e.g. "ddclient.*") |
; - true : Regular expression search (used pgrep command) |
; - false : Normal search (used pidof command) |
; |
USE_REGEX=false |
|
; controls which processes are checked if they are running |
; |
; string contains a list of process names that are checked, names are seperated by a comma (on WINNT names must end with '.exe') |
; |
PROCESSES="mysqld, sshd, explorer.exe" |
|
|
[quotas] |
; Quotas Plugin configuration |
|
; define how to access the repquota statistic data |
; - "command" repquota command is run everytime the block gets refreshed or build |
; - "data" (a file must be available in the data directory of the phpsysinfo installation with the filename "quotas.txt"; content is the output from "repquota -au") |
; |
ACCESS="command" |
|
|
[smart] |
; SMART Plugin configuration |
|
; Smartctl program |
; If the smartctl program is available we can read S.M.A.R.T informations |
; - "command" smartctl command is run everytime the block gets refreshed or build |
; if error: Smartctl open device: /dev/sda failed: Permission denied |
; Not recommended method: |
; execute: chmod 4755 /usr/sbin/smartctl |
; Second method: |
; try to set: SUDO_COMMANDS="smartctl" and add to file /etc/sudoers line: apache ALL = (ALL) NOPASSWD: /usr/sbin/smartctl |
; - "data" (a file must be available in the data directory of the |
; phpsysinfo installation with the filename "smart{disk_number}.txt"; |
; content is the output from "smartctl --all device") |
; - "wmi" information is retrieved everytime through WMI (WinNT only) |
; |
ACCESS="command" |
|
; Smartctl devices to monitor |
; If the smartctl support is enabled, those disks information will be displayed |
; - DEVICES="/dev/hda,/dev/hdb" //Will display those two disks informations |
; You also can specify --device option value for smartctl command surrounded by parentheses eg: |
; - DEVICES="(marvell)/dev/sda" |
; or |
; - DEVICES="(megaraid.0)/dev/sda" //comma in --device option value is replaced by a dot |
; |
DEVICES="/dev/sda, /dev/sdb" |
|
; Smartctl ID# and column name from "Vendor Specific SMART Attributes with Thresholds" table |
; If the smartctl support is enabled, enter the ID#-COLUMN_NAME from "Vendor Specific SMART Attributes with Thresholds" table from smartctl output. |
; or for no SCSI devices: ID#-COLUMN_NAME-REPLACEMENT_ID# where REPLACEMENT_ID# is an alternative ID number. |
; COLUMN_NAME of this ID# will be displayed in the phpsysinfo S.M.A.R.T table. If you want RAW_VALUE to be displayed for the temperature (ID# 194) enter 194-RAW_VALUE |
; - IDS="194-VALUE,4-VALUE,009-RAW_VALUE" //ID#-COLUMN_NAME, ID#-COLUMN_NAME, etc... |
; |
IDS="005-RAW_VALUE,194-RAW_VALUE,4-RAW_VALUE,009-RAW_VALUE,012-RAW_VALUE,193-RAW_VALUE-225,001-RAW_VALUE,007-RAW_VALUE,200-RAW_VALUE,197-RAW_VALUE,198-RAW_VALUE" |
|
|
[snmppinfo] |
; SNMPPInfo Plugin configuration |
|
; define how to access the SNMP Printer Info statistic data |
; - "php-snmp" execute php snmprealwalk function (php-snmp module must be installed) |
; - "command" execute snmpwalk command |
; - "data" a file must be available in the data directory of the |
; phpsysinfo installation with the filename "snmppinfo{printer_number}.txt"; |
; content is the output from: |
; LANG=C LC_ALL=C snmpwalk -On -c public -v 1 -r 0 -t 3 {printer_address} .1.3.6.1.2.1.1.5 > snmppinfo{printer_number}.txt |
; LANG=C LC_ALL=C snmpwalk -On -c public -v 1 -r 0 -t 3 {printer_address} .1.3.6.1.4.1.367.3.2.1.2.24.1.1 >> snmppinfo{printer_number}.txt |
; LANG=C LC_ALL=C snmpwalk -On -c public -v 1 -r 0 -t 3 {printer_address} .1.3.6.1.2.1.43.11.1.1 >> snmppinfo{printer_number}.txt |
; LANG=C LC_ALL=C snmpwalk -On -c public -v 1 -r 0 -t 3 {printer_address} .1.3.6.1.2.1.43.18.1.1 >> snmppinfo{printer_number}.txt |
; |
ACCESS="php-snmp" |
|
;define the Printer devices |
; |
; string contains a list of printer addresses that are checked |
; |
DEVICES="192.168.0.5, 192.168.0.9" |
|
|
[updatenotifier] |
; Update Notifier Plugin configuration |
|
; define how to access the updatenotifier statistic data |
; - "command" execute command /usr/lib/update-notifier/apt-check |
; - "data" reads data from file defined in FILE parameter |
; |
ACCESS="data" |
|
; define the update info file format |
; - true: Ubuntu Landscape format (file: /var/lib/update-notifier/updates-available) |
; - false: universal format (format: A;B) |
; A: total packages to update |
; B: security packages to update |
; |
UBUNTU_LANDSCAPE_FORMAT=true |
|
; define the update info file. The default is: /var/lib/update-notifier/updates-available |
; |
FILE="/var/lib/update-notifier/updates-available" |
|
|
[uprecords] |
; Uprecords Plugin configuration |
|
; define how to access the uprecords statistic data |
; - "command" uprecords command is run everytime the block gets refreshed or build |
; if access error try execute first: chmod 4755 /usr/bin/uprecords |
; This method is not recommended for safety reasons! |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "uprecords.txt"; content is the output from "TZ=GMT uprecords -a -w") |
; |
ACCESS="command" |
|
; define the maximum number of entries to show (for command access) |
; default is 10 |
; |
MAX_ENTRIES = 10 |
|
; define the short mode (do not print extra statistics) |
; default is false |
; |
SHORT_MODE = false |
|
; denote current system session by asterisk (* at the end) instead by the arrow (-> at the beginning) |
; default is false |
; |
DENOTE_BY_ASTERISK = false |
|
|
[iptables] |
; Iptables Plugin configuration |
|
; define how to access the iptables rules data |
; - "command" iptables-save command is run everytime the block gets refreshed or build |
; if access error try to set: SUDO_COMMANDS="iptables-save" and add to file /etc/sudoers line: apache ALL = (ALL) NOPASSWD: /sbin/iptables-save |
; - "data" (a file must be available in the data directory of the phpsysinfo installation with the filename "iptables.txt"; content is the output from "iptables-save") |
; |
ACCESS="command" |
|
|
[pingtest] |
; PingTest Plugin configuration |
|
; define how to access the psstatus statistic data |
; - "command" ping command is run everytime the block gets refreshed or build |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "pingtest.txt") |
; |
ACCESS="command" |
|
;define the Addresses |
; |
; string contains a list of addresses that are checked |
; Example : ADDRESSES="127.0.0.1,8.8.8.8" |
; |
ADDRESSES="" |
|
; Define ping timeout in seconds |
; - 0 : default ping command timeout |
; - 3 : 3 seconds |
; Default is 2 seconds |
; |
TIMEOUT=2 |
|
[stablebit] |
; StableBit Plugin configuration |
|
; Show or hide disks serial number |
; |
SHOW_SERIAL=false |
|
[hyperv] |
; HyperV Plugin configuration |
|
; define how to access the ps statistic data |
; - "command" information is retrieved through WMI |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "hyperv.txt") |
; |
ACCESS="command" |
|
[docker] |
; Docker Plugin configuration |
|
; define how to access the docker statistic data |
; - "command" docker command is run everytime the block gets refreshed or build |
; - "data" (a file must be available in the data directory of the phpsysinfo installation |
; with the filename "docker.txt"; content is the output from "docker stats --no-stream --format 'table {{.Name}}\t{{.CPUPerc}}\t{{.MemUsage}}\t{{.MemPerc}}\t{{.NetIO}}\t{{.BlockIO}}\t{{.PIDs}}'") |
; |
ACCESS="command" |